Systemair RVK Fans no longer need to be wired up - you just require a separate IEC Lead & Plug
Climate control can be easy and affordable – the German made RVK Systemair Extractor Fans see to that.
They’re robust, powerful and quiet, yet extremely low cost. You’ll connect and install them in no time at all. It’s no wonder they’re our bestselling fan!
Believe us, they will not let you down. They’ve been tried and tested time and time again – they’re virtually indestructible with airtight casing! Yours will safely run for 24 hours a day without stopping
You won’t find a fan this good for such a low cost anywhere else. It’s an absolute must for entry-level growers! Experienced growers still swear by them.
Use air vents or a second, smaller RVK extractor fan to draw air in
Please see ‘The Tech’ to work out which size fans you need.
Choosing A Carbon Filter
To remove foul odours, you need to use a carbon filter with your extractor fan. Make sure your carbon filter’s spigot/flange size is the same as that in your extractor fan. Here are the carbon filters compatible with each fan:
• Max. airflow: 184m3/h • Flange size: 99mm • Max power consumption: 29W • Sound pressure level at 3 m: 34.5 dB(A) • Voltage: 230V • Frequency: 50Hz • Phase: 1~ • Input power: (P1) 29.1 W • Current: 0.171 A • R.p.m: 2482 • Weight: 1.8kg • Max. temperature of transported air: 70°C • Max. temperature of transported air when speed-controlled: 70°C • Insulation class: B • Enclosure class, motor: IP44
125mm (5") RVK125 A1 Extractor Fan - 220m3/hour
• Max. airflow: 220 m3/h • Flange size: 124mm • Max power consumption: 29W • Sound pressure level at 3m: 37.5 dB(A) • Voltage: 230V • Frequency: 50Hz • Phase: 1 ~ • Input power (P1): 29.2W • Current: 0.172 A • R.p.m: 2469 • Weight: 1.8kg • Max. temperature of transported air 70°C • Max. temperature of transported air when speed-controlled 70°C • Insulation class: B • Insulation class: B • Enclosure class, motor :IP44
150mm (6") RVK150 A1 Extractor Fan - 430m3/hour
• Max. airflow: 430 m3/h • Flange size: 149mm • Max power consumption: 60W • Sound pressure level at 3m: 40.6 dB(A) • Voltage: 230V • Frequency: 50 Hz • Phase: 1 ~ • Input power (P1): 59.6W • Current: 0.262 A • R.p.m.: 2437 • Capacitor: 2 µF • Weight: 2.7kg • Max. temperature of transported air: 70°C • Max. temperature of transported air when speed-controlled: 70°C • Insulation class: B • Enclosure class, motor: IP44
150mm (6") RVK150 L1 Extractor Fan - 720m3/hour
• Max. airflow: 720m3/h • Flange size: 149mm • Max power consumption: 109W • Sound pressure level at 3 m: 44.8 dB(A) • Voltage: 230V • Frequency: 50 Hz • Phase: 1 ~ • Input power (P1): 109W • Current: 0.48 A • R.p.m.: 2527 • Capacitor: 3 µF • Weight : 3.2kg • Max. temperature of transported air: 70°C • Max. temperature of transported air when speed-controlled: 70°C • Insulation class: F • Enclosure class, motor: IP44 IP • Energy class, basic unit: E • Energy class, basic unit option: C • ErP ready: ErP 2016/ErP 2018
200mm (8") RVK200 A1 Extractor Fan - 796m3/hour
• Max. airflow: 796 m3/h • Flange size: 199mm • Max power consumption: 104W • Sound pressure level at 3 m: 42 dB(A) • Voltage: 230V • Frequency: 50 Hz • Phase: 1 ~ • Input power (P1): 104W • Current: 0.46 A • R.p.m.: 2495 • Capacitor: 3 µF • Weight : 3.3kg • Max. temperature of transported air: 70°C • Max. temperature of transported air when speed-controlled: 70°C • Insulation class: F • Enclosure class, motor: IP44 • Energy class, basic unit: E • Energy class, basic unit option: B • ErP ready: ErP 2016/ErP 2018
250mm (10") RVK250 L1 Extractor Fan - 1100m3/hour
• Max. airflow: 1100 m3/h • Flange size: 249mm • Max power consumption: 159W • Sound pressure level at 3 m: 41.9 dB(A) • Voltage: 230V • Frequency: 50 Hz • Phase: 1 ~ • Input power (P1): 159 W • Current: 0.691 A • R.p.m: 2531 • Capacitor: 4 µF • Weight: 3.9kg • Max. temperature of transported air: 70°C • Max. temperature of transported air when speed-controlled: 70°C • Insulation class: F • Enclosure class, motor: IP44 IP • Energy class, basic unit: E • Energy class, basic unit option: B • ErP ready: ErP 2016/ErP 2018
315mm (12.5") RVK315 A1 Extractor Fan - 1346m3/hour
• Max. airflow: 1346 m3/h • Flange size: 314mm • Max power consumption: 222W • Sound pressure level at 3 m: 45 dB(A) • Voltage: 230V • Frequency: 50 Hz • Phase: 1 ~ • Input power (P1): 222W • Current: 0.971 A • R.p.m.: 2696 • Capacitor: 5 µF • Weight : 5.2 kg • Max. temperature of transported air: 70°C • Max. temperature of transported air when speed-controlled: 70°C • Insulation class: B • Enclosure class, motor: IP44 IP • ErP ready: ErP 2018/ErP 2016
How to Use
Connect a Power Lead to the Fan
The fan comes with an IEC connection, you will need to use a power cable to connect it to power. Buy 5m IEC plug & Lead separately here.
Identify the Direction of Air Flow
Air needs to travel out of your growing area for extraction, or into your growing area for intake. There’s an arrow on the fan’s case to show you which way the air travels.
Connecting up the Equipment
Attach a suitable length of ducting to the exhaust side of the fan, using a duct clip and then feed the ducting through the duct port in your tent, or to the area you wish to vent to.
Attach the other end of the fan to your filter using a fast clamp or small piece of ducting and a duct clip.
Hanging the Extraction System
It can be difficult getting the system into position on your own, but not impossible – we recommend using rope ratchets.
https://www.growell.co.uk/systemair-rvk-extractor-fans.html3645Systemair RVK Extractor Fanshttps://www.growell.co.uk/media/catalog/product/s/y/systemair-rvk-extractor-fan_web.jpg55.2164.95GBPInStock/Fans, Filters & Environment/Fans, Filters & Environment/Extractor Fans<!--GENE_CMS="[{"type":"row","formData":{"template":"row.phtml","background_color":"","background_image":"","css_classes":"","undefined":"","align":"","metric":""},"children":[{"type":"column","formData":{"width":"0.500"},"children":[{"contentType":"textarea","entityId":"7112","formData":{"align":"","metric":""}},{"contentType":"textarea","entityId":"7113","formData":{"align":"","metric":""}},{"contentType":"heading","entityId":"7121","formData":{"align":"","metric":""}},{"contentType":"textarea","entityId":"7122","formData":{"align":"","metric":""}}]},{"type":"column","formData":{"width":"0.500"},"children":[{"contentType":"heading","entityId":"7115","formData":{"align":"","metric":""}},{"contentType":"textarea","entityId":"7116","formData":{"align":"","metric":""}},{"contentType":"heading","entityId":"7117","formData":{"align":"","metric":""}},{"contentType":"textarea","entityId":"7118","formData":{"align":"","metric":""}},{"contentType":"heading","entityId":"7119","formData":{"align":"","metric":""}},{"contentType":"textarea","entityId":"7120","formData":{"align":"","metric":""}}]}]}]"--> <div data-content-type="row" data-appearance="contained" data-element="main"><div data-enable-parallax="0" data-parallax-speed="0.5" data-background-images="{}" data-video-fallback-src="" data-element="inner" style="justify-content: flex-start; display: flex; flex-direction: column; background-position: left top; background-size: cover; background-repeat: no-repeat; background-attachment: scroll; border-style: none; border-width: 1px; border-radius: 0px; margin: 0px 0px 10px; padding: 10px;"><h2 data-content-type="heading" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px;">Overview</h2><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><p id="EFE4216"><span style="color: #96bf32;"><strong id="RXW6WPY">Systemair RVK Fans no longer need to be wired up - you just require a separate IEC Lead & Plug</strong></span></p></div><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><div class="bluefoot-textarea bluefoot-entity">
<p>Climate control can be<strong> easy</strong> and <strong>affordable</strong> – the <strong>German made RVK Systemair Extractor Fans</strong> see to that.</p>
<p>They’re <strong>robust, powerful</strong> and <strong>quiet</strong>, yet extremely<strong> low cost</strong>. You’ll connect and install them in no time at all. It’s no wonder they’re<strong> our bestselling fan</strong>!</p>
<p>Believe us, they will not let you down. They’ve been<strong> tried and tested</strong> time and time again – they’re <strong>virtually indestructible</strong> with <strong>airtight casing</strong>! Yours will safely run for 24 hours a day without stopping</p>
<p>You won’t find a fan this good for such a low cost anywhere else. It’s an absolute must for entry-level growers!<strong> Experienced growers still swear by them</strong>.</p>
</div>
<div class="bluefoot-textarea bluefoot-entity">
<ul>
<li>Designed to run 24/7</li>
<li><strong>Easily connects</strong> to carbon filters and silencers</li>
<li>It’s a <strong>bestseller</strong>!</li>
<li>Systemair – a <strong>trusted brand</strong></li>
<li><strong>Quiet</strong> with<strong> low vibration</strong></li>
<li><strong>Maintenance-free</strong> and <strong>highly reliable</strong></li>
<li>Ideal as<strong> an extractor fan</strong> and<strong> intake fan</strong></li>
<li><strong>Speed-controllable</strong></li>
<li>Integral thermal contacts</li>
<li><strong>Flexible!</strong> Can be installed in any position</li>
<li><strong>Mounting bracket included</strong></li>
</ul>
<p> </p>
</div></div><h2 data-content-type="heading" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px;">Try A Complete Kit</h2><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><p>To make life easy, opt for a complete <a href="https://www.growell.co.uk/eco-extraction-kits.html" target="_blank" rel="noopener">Eco Extraction Kit</a>. You don’t have to work anything out – kits come with an RVK Extraction Fan, a <a href="https://www.growell.co.uk/grow-room-tools/other-tools-hardware/iec-lead-plug-3m.html" target="_blank" rel="noopener">5m Power Cable</a> a <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">PK Eco Carbon Filter</a>, <a href="https://www.growell.co.uk/combi-flexible-fan-ducting.html" target="_blank" rel="noopener">5m Combi Ducting</a> and <a href="https://www.growell.co.uk/quick-release-duct-clip.html" target="_blank" rel="noopener">3 x Quick Release Duct Clips</a></p>
<p id="DNN14M0">Or try going Pro with the Professional Extraction Kit - you get an RVK Extractor Fan, a <a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 Carbon Filter</a>, <a href="https://www.growell.co.uk/grow-room-tools/other-tools-hardware/iec-lead-plug-3m.html" target="_blank" rel="noopener">5m Power Cable</a>, <a href="https://www.growell.co.uk/fans-filters-environment/ducting-accessories/combi-flexible-fan-ducting.html" target="_blank" rel="noopener">5m Combi Ducting</a>, a <a href="https://www.growell.co.uk/fans-filters-environment/ducting-accessories/fast-clamps.html" target="_blank" rel="noopener">Fast Clamp</a> and a <a href="https://www.growell.co.uk/fans-filters-environment/ducting-accessories/quick-release-duct-clip.html" target="_blank" rel="noopener">Quick Release Duct Clip</a>. </p></div></div></div><div data-content-type="row" data-appearance="contained" data-element="main"><div data-enable-parallax="0" data-parallax-speed="0.5" data-background-images="{}" data-video-fallback-src="" data-element="inner" style="justify-content: flex-start; display: flex; flex-direction: column; background-position: left top; background-size: cover; background-repeat: no-repeat; background-attachment: scroll; border-style: none; border-width: 1px; border-radius: 0px; margin: 0px 0px 10px; padding: 10px;"><h2 data-content-type="heading" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px;">You Will Also Need</h2><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><ul>
<li>A separate <a href="https://www.growell.co.uk/grow-room-tools/other-tools-hardware/iec-lead-plug-3m.html" target="_blank" rel="noopener">5m power cable </a>for each fan</li>
<li>A <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">carbon filter</a> (extractor only)</li>
<li>A suitable length of <a href="https://www.growell.co.uk/combi-flexible-fan-ducting.html" target="_blank" rel="noopener">Ducting</a></li>
<li><a href="https://www.growell.co.uk/quick-release-duct-clip.html" target="_blank" rel="noopener">3 x Quick Release Duct Clips</a> (or <a href="https://www.growell.co.uk/fast-clamps.html">1 x Fast Clamp</a> and <a href="https://www.growell.co.uk/quick-release-duct-clip.html" target="_blank" rel="noopener">2 x Quick Release Duct Clips</a>)</li>
<li><a href="https://www.growell.co.uk/exolux-pro-rope-ratchet-heavy-duty-hangers.html" target="_blank" rel="noopener">2 x Rope Ratchets</a> (recommended)</li>
</ul></div><h2 data-content-type="heading" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px;">Choosing Your Fan</h2><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><ul>
<li>Use one fan to draw air out of your grow room</li>
<li>Use air vents or a second, smaller RVK extractor fan to draw air in</li>
</ul>
<p>Please see ‘The Tech’ to work out which size fans you need.</p></div><h2 data-content-type="heading" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px;">Choosing A Carbon Filter</h2><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><div class="bluefoot-textarea bluefoot-entity">
<p>To remove foul odours, you need to use a carbon filter with your extractor fan. Make sure your carbon filter’s spigot/flange size is the same as that in your extractor fan. Here are the carbon filters compatible with each fan:</p>
<p><strong>100mm (4") RVK100 A1 Extractor Fan - 184m3/hour:</strong> <a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 100/330</a> or <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">BF160</a><br><strong>125mm (5") RVK125 A1 Extractor Fan - 220m3/hour: </strong><a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 125/330</a> or <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">BF240</a><br><strong>150mm (6") RVK150 A1 Extractor Fan - 430m3/hour:</strong> <a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 150/330</a> or <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">BF360</a><br><strong>150mm (6") RVK150 L1 Extractor Fan - 720m3/hour: </strong><a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 150/660</a> or <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">BF680</a><br><strong>200mm (8") RVK200 A1 Extractor Fan - 796m3/hour:</strong> <a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 200/660</a> or <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">BF800</a><br><strong>250mm (10") RVK250 L1 Extractor Fan - 1100m3/hour:</strong> <a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 250/660</a> or <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">BF1000</a><br><strong>315mm (12.5") RVK315 A1 Extractor Fan - 1346m3/hour:</strong> <a href="https://www.growell.co.uk/fans-filters-environment/carbon-filters/carboair-50-carbon-filters.html" target="_blank" rel="noopener">CarboAir 50 315/660</a> or <a href="https://www.growell.co.uk/prima-klima-eco-carbon-filters.html" target="_blank" rel="noopener">BF1300</a></p>
</div></div></div></div><div data-content-type="row" data-appearance="contained" data-element="main"><div data-enable-parallax="0" data-parallax-speed="0.5" data-background-images="{}" data-video-fallback-src="" data-element="inner" style="justify-content: flex-start; display: flex; flex-direction: column; background-position: left top; background-size: cover; background-repeat: no-repeat; background-attachment: scroll; border-style: none; border-width: 1px; border-radius: 0px; margin: 0px 0px 10px; padding: 10px;"><h2 data-content-type="heading" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px;">The Tech</h2><div class="pagebuilder-column-group" style="display: flex;" data-content-type="column-group" data-grid-size="12" data-element="main"><div class="pagebuilder-column" data-content-type="column" data-appearance="full-height" data-background-images="{}" data-element="main" style="justify-content: flex-start; display: flex; flex-direction: column; background-position: left top; background-size: cover; background-repeat: no-repeat; background-attachment: scroll; border-style: none; border-width: 1px; border-radius: 0px; width: 50%; margin: 0px; padding: 10px; align-self: stretch;"><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><p><strong>100mm (4") RVK100 A1 Extractor Fan - 184m3/hour</strong></p>
<p> </p>
<p>• Max. airflow: 184m3/h<br>• Flange size: 99mm<br>• Max power consumption: 29W<br>• Sound pressure level at 3 m: 34.5 dB(A)<br>• Voltage: 230V<br>• Frequency: 50Hz<br>• Phase: 1~<br>• Input power: (P1) 29.1 W<br>• Current: 0.171 A<br>• R.p.m: 2482<br>• Weight: 1.8kg<br>• Max. temperature of transported air: 70°C<br>• Max. temperature of transported air when speed-controlled: 70°C<br>• Insulation class: B<br>• Enclosure class, motor: IP44</p>
<p> </p>
<p><strong>125mm (5") RVK125 A1 Extractor Fan - 220m3/hour</strong></p>
<p> </p>
<p>• Max. airflow: 220 m3/h<br>• Flange size: 124mm<br>• Max power consumption: 29W<br>• Sound pressure level at 3m: 37.5 dB(A)<br>• Voltage: 230V<br>• Frequency: 50Hz<br>• Phase: 1 ~<br>• Input power (P1): 29.2W<br>• Current: 0.172 A<br>• R.p.m: 2469<br>• Weight: 1.8kg<br>• Max. temperature of transported air 70°C<br>• Max. temperature of transported air when speed-controlled 70°C<br>• Insulation class: B<br>• Insulation class: B<br>• Enclosure class, motor :IP44</p>
<p> </p>
<p><strong>150mm (6") RVK150 A1 Extractor Fan - 430m3/hour</strong></p>
<p> </p>
<p>• Max. airflow: 430 m3/h<br>• Flange size: 149mm<br>• Max power consumption: 60W<br>• Sound pressure level at 3m: 40.6 dB(A)<br>• Voltage: 230V<br>• Frequency: 50 Hz<br>• Phase: 1 ~<br>• Input power (P1): 59.6W<br>• Current: 0.262 A<br>• R.p.m.: 2437<br>• Capacitor: 2 µF<br>• Weight: 2.7kg<br>• Max. temperature of transported air: 70°C<br>• Max. temperature of transported air when speed-controlled: 70°C<br>• Insulation class: B<br>• Enclosure class, motor: IP44</p>
<p> </p>
<p><strong>150mm (6") RVK150 L1 Extractor Fan - 720m3/hour</strong></p>
<p> </p>
<p>• Max. airflow: 720m3/h<br>• Flange size: 149mm<br>• Max power consumption: 109W<br>• Sound pressure level at 3 m: 44.8 dB(A)<br>• Voltage: 230V<br>• Frequency: 50 Hz<br>• Phase: 1 ~<br>• Input power (P1): 109W<br>• Current: 0.48 A<br>• R.p.m.: 2527<br>• Capacitor: 3 µF<br>• Weight : 3.2kg<br>• Max. temperature of transported air: 70°C<br>• Max. temperature of transported air when speed-controlled: 70°C<br>• Insulation class: F<br>• Enclosure class, motor: IP44 IP<br>• Energy class, basic unit: E<br>• Energy class, basic unit option: C<br>• ErP ready: ErP 2016/ErP 2018</p></div></div><div class="pagebuilder-column" data-content-type="column" data-appearance="full-height" data-background-images="{}" data-element="main" style="justify-content: flex-start; display: flex; flex-direction: column; background-position: left top; background-size: cover; background-repeat: no-repeat; background-attachment: scroll; border-style: none; border-width: 1px; border-radius: 0px; width: 50%; margin: 0px; padding: 10px; align-self: stretch;"><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><p><strong>200mm (8") RVK200 A1 Extractor Fan - 796m3/hour</strong></p>
<p> </p>
<p>• Max. airflow: 796 m3/h<br>• Flange size: 199mm<br>• Max power consumption: 104W<br>• Sound pressure level at 3 m: 42 dB(A)<br>• Voltage: 230V<br>• Frequency: 50 Hz<br>• Phase: 1 ~<br>• Input power (P1): 104W<br>• Current: 0.46 A<br>• R.p.m.: 2495<br>• Capacitor: 3 µF<br>• Weight : 3.3kg<br>• Max. temperature of transported air: 70°C<br>• Max. temperature of transported air when speed-controlled: 70°C<br>• Insulation class: F<br>• Enclosure class, motor: IP44<br>• Energy class, basic unit: E<br>• Energy class, basic unit option: B<br>• ErP ready: ErP 2016/ErP 2018</p>
<p> </p>
<p><strong>250mm (10") RVK250 L1 Extractor Fan - 1100m3/hour</strong></p>
<p> </p>
<p>• Max. airflow: 1100 m3/h<br>• Flange size: 249mm<br>• Max power consumption: 159W<br>• Sound pressure level at 3 m: 41.9 dB(A)<br>• Voltage: 230V<br>• Frequency: 50 Hz<br>• Phase: 1 ~<br>• Input power (P1): 159 W<br>• Current: 0.691 A<br>• R.p.m: 2531<br>• Capacitor: 4 µF<br>• Weight: 3.9kg<br>• Max. temperature of transported air: 70°C<br>• Max. temperature of transported air when speed-controlled: 70°C<br>• Insulation class: F<br>• Enclosure class, motor: IP44 IP<br>• Energy class, basic unit: E<br>• Energy class, basic unit option: B<br>• ErP ready: ErP 2016/ErP 2018</p>
<p> </p>
<p><strong>315mm (12.5") RVK315 A1 Extractor Fan - 1346m3/hour</strong></p>
<p> </p>
<p>• Max. airflow: 1346 m3/h<br>• Flange size: 314mm<br>• Max power consumption: 222W<br>• Sound pressure level at 3 m: 45 dB(A)<br>• Voltage: 230V<br>• Frequency: 50 Hz<br>• Phase: 1 ~<br>• Input power (P1): 222W<br>• Current: 0.971 A<br>• R.p.m.: 2696<br>• Capacitor: 5 µF<br>• Weight : 5.2 kg<br>• Max. temperature of transported air: 70°C<br>• Max. temperature of transported air when speed-controlled: 70°C<br>• Insulation class: B<br>• Enclosure class, motor: IP44 IP<br>• ErP ready: ErP 2018/ErP 2016</p></div></div></div></div></div><div data-content-type="row" data-appearance="contained" data-element="main"><div data-enable-parallax="0" data-parallax-speed="0.5" data-background-images="{}" data-video-fallback-src="" data-element="inner" style="justify-content: flex-start; display: flex; flex-direction: column; background-position: left top; background-size: cover; background-repeat: no-repeat; background-attachment: scroll; border-style: none; border-width: 1px; border-radius: 0px; margin: 0px 0px 10px; padding: 10px;"><h2 data-content-type="heading" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px;">How to Use</h2><div data-content-type="text" data-appearance="default" data-element="main" style="border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;"><p><strong>Connect a Power Lead to the Fan</strong><br><br></p>
<p>The fan comes with an IEC connection, you will need to use a power cable to connect it to power. Buy 5m IEC plug & Lead separately <a href="https://www.growell.co.uk/grow-room-tools/other-tools-hardware/iec-lead-plug-3m.html">here.</a></p>
<p><br><strong>Identify the Direction of Air Flow</strong><br><br>Air needs to travel out of your growing area for extraction, or into your growing area for intake. There’s an arrow on the fan’s case to show you which way the air travels.<br><br><strong>Connecting up the Equipment</strong><br><br>Attach a suitable length of ducting to the exhaust side of the fan, using a duct clip and then feed the ducting through the duct port in your tent, or to the area you wish to vent to.<br><br>Attach the other end of the fan to your filter using a fast clamp or small piece of ducting and a duct clip.<br><br><strong>Hanging the Extraction System<br></strong><br>It can be difficult getting the system into position on your own, but not impossible – we recommend using rope ratchets.</p></div></div></div>00https://www.growell.co.uk/media/catalog/product/f/a/fan-set-up_web.jpghttps://www.growell.co.uk/media/catalog/product/d/u/ducting-alt-web.jpghttps://www.growell.co.uk/media/catalog/product/r/v/rvkgroup-alt-web.jpghttps://www.growell.co.uk/media/catalog/product/e/x/extract-intake-web.jpghttps://www.growell.co.uk/media/catalog/product/i/n/in-tent-alt-web.jpghttps://www.growell.co.uk/media/catalog/product/i/n/intake-alt-web.jpghttps://www.growell.co.uk/media/catalog/product/a/s/assembly-2_web.jpghttps://www.growell.co.uk/media/catalog/product/e/x/extraction-kit-3_web.jpghttps://www.growell.co.uk/media/catalog/product/e/x/extraction-kit-2_web.jpgrating:98.4excluded_from_sitemap:No